Air respirator fast charging
Complies with the national standard XF124-2013 for positive pressure fire-fighting air respirators;
Keyword:
Classification:
Air respirator accessories
Positive Pressure Air Breathing Apparatus Quick Charging Instructions
1. Complies with the national standard XF124-2013 "Positive Pressure Firefighting Air Breathing Apparatus"; has high temperature resistance, flame retardant, insulation, explosion-proof, corrosion resistance, waterproof, and good airtightness.
2. Quick charging device: can quickly inflate the cylinder without removing it, convenient to use, and highly reliable. Achieves bottle-to-bottle rapid charging.
Qualification Assessment Form
The input connector of the quick inflation device should be installed at the fixed position of the respirator. . | Qualified |
The output connector of the quick inflation device should match the input connector, and there should be no leakage after connection. | Qualified |
The input and output connectors of the quick inflation device should have protective covers, each sealing itself. | Qualified |
The connecting pipe of the quick inflation device should undergo a water pressure test at twice the nominal working pressure of the cylinder without leakage or abnormal deformation. The output connector of the quick inflation device should be able to connect or disconnect with one hand at a cylinder pressure of 30MPa. | Qualified |
When charging between cylinders of the same nominal volume, the time for the cylinder pressure to balance should not exceed 1 minute. Input Connector Size | Qualified |
The external dimensions of the input connector +0.31 | Qualified |
+0.25
+0.14 | 3.5 +0.33 0 | 3.53mm | |
5 31.5±0.3 0 | 5.07mm | ||
5.9 -0.08 0 | 6.01mm | ||
11.11±0.05 0 | 11.32mm | ||
1.02 mm | 31.76mm | ||
23.70 30° ±1.5 | 23.68mm | ||
16.1 0 30° ±1.5 | 16.09mm | ||
13.2 0 30° ±1.5 | 13.18mm | ||
30.4° | Cylinder pressure 6MPa | ||
Breathing volume 40×2.5L/min | Positive pressure should always be maintained inside the full face mask. | ||
Exhalation resistance ≤1000Pa. 663 Pa | 全面罩内应始终保持正压。 | Qualified | |
呼气阻力≤1000Pa。 | 663 Pa |
Contact Us
Service Phone:
Contact E-mail:
Contact Address:
100 meters south of Chengnan Chenzhuang Junction, National Highway 220, Changqing District, Jinan City, Shandong Province
What makes us so different from other suppliers?
The company is committed to the research and development and production of personal protective equipment for emergency rescue, and at the same time supporting the sales service and training of related safety protection equipment and equipment.
Strong Strength
Shandong Haiante company was founded in 2003, covers an area of 15,000 square meters, more than 30 professional R & D technicians, 3 senior engineers.

Qualification
The products have obtained the special product production license issued by the quality supervision department and passed the type inspection and some certifications of the National Fire Equipment Quality Center.

After-sales Service
The products cover 26 provinces, more than 500 cities, and more than 10 surrounding countries, providing personal protective equipment support for more than 20000 workers across the country every year

After-sales Service
We provide timely, complete and comprehensive pre-sales, in-sales, after-sales, and services for all Hyant users, so that products and services follow each other, and continuously improve the overall service quality of the company is our service goal.

Need help? We're here to help!
Please contact us to provide you with satisfactory products and become a reliable supplier and service provider in the industry.
Other Products
Occupational safety and health special protective equipment, fire emergency rescue individual protective equipment
Isolated Positive Pressure Oxygen Breathing Apparatus (Cabin Type)
Positive pressure oxygen respirator (bag type)
Positive pressure fire-fighting oxygen respirator
Oxygen respirator packaging box